User Facilities

FRIB also offers stable and long-lived radioactive beams that may be run at ReA3, ReA6, or the stopped beam area in stand-alone mode (that is, not coupled to the FRIB linac).

FRIB primary beams

Demonstrated and available (updated 28 July 2025)

Please note: the best effort will be made to use the full primary beam current on the FRIB target. However, the full beam intensity may not be able to be used for all experiments due to potential limitations arising in the final optimized setting. FRIB is planning to demonstrate higher beam currents for selected primary beams which will then become available. 

Isotope Energy (MeV/u) Beam current 
on FRIB target 
(particle nA)
16O1607813
18O1606944
22Ne1705348
22Ne2651730
28Si2502857
28Si3001190
36Ar2502222
36Ar300926
40Ar2502000
40Ca2502000
40Ca300833
48Ca2321796
48Ca2401215
58Ni2501379
64Ni235864
64Zn2501250
70Zn2301242
70Ge246581
78Kr2471038
86Kr2281020
82Se2271074
92Mo238114
124Xe240672
198Pt188185
209Bi188255
238U177475

*pps = pnA x 6.25 x 109
pps = particles per second
pnA = particle nanoampere

Being developed next

Isotope Energy (MeV/u) 
144Sm215
208Pb188

Rare isotope beam rates

Rare isotope beam rates used in proposals must be calculated by an FRIB beam scientist. 

An approximate estimate can be obtained from the calculator. The estimates available on the web-based calculator assume optimal conditions and are only intended to provide a rough indication of experiment feasibility. Actual rates will likely be less. Rates above 1E8 pps will require a detailed evaluation of primary beam and fragment power deposition and may not be possible.

For further information on how rates are calculated, please review this tutorial: LISE++ tutorial: Making 64Cr

Beam list for stand-alone operation at ReA3, ReA6, or Stopped Beam Area

The PDF list below includes stable and long-lived radioactive beams that may be run at ReA3, ReA6, or the stopped beam area in stand-alone mode (that is, not coupled to the FRIB linac).

Please note that beams of long-lived and rare stable isotopes are subject to availability of material at the time of the experiment. Beams that are not on the beam list may be requested in discussion with the stopped and reaccelerated beam operations department.

ReA3, ReA6, stopped beam area list of beams

The beam rate calculator provides a preliminary estimate based on optimal conditions, offering a general indication of experiment feasibility.

Visit the calculator

Michigan State University (MSU) operates the Facility for Rare Isotope Beams (FRIB) as a user facility for the U.S. Department of Energy Office of Science(link is external) (DOE SC), with financial support from and furthering the mission of the DOE‑SC Office of Nuclear Physics. FRIB is registered to ISO 9001, ISO 14001, ISO 27001, and ISO 45001.

Michigan State University U.S. Department of Energy